In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

An automated method for assessing routine radiographs of patients with total hip replacements

Redhead, A L; Kotcheff, A C W; Taylor, C J; Porter, M L; Hukins, D W L

Proceedings of the Institution of Mechanical Engineers Part H - Journal of Engineering in Medicine. 1997;211(2):145-154.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Use our list of Related resources to find this item elsewhere. Alternatively, request a copy from the Library's Document supply service.

Abstract

This paper describes a new, fully automated method of locating objects on radiographs of patients with total joint replacements (TJRs). A statistical computer model, known as an active shape model, was trained to identify the position of the femur, pelvis, stem and cup marker wire on radiographs of patients with Charnley total hip prostheses. Once trained, the model was able to locate these objects through a process of automatic image searching, despite their appearance depending on the orientation and anatomy of the patient. Experiments were carried out to test the accuracy with which the model was able to fit to previously unseen data and with which reference points could be calculated from the model points. The model was able to locate the femur and stem with a mean error of approximately 0.8 mm and a 95 per cent confidence limit of 1.7 mn. Once the model had successfully located these objects, the midpoint of the stem head could be calculated with a mean error of approximately 0.2 mm. Although the model has been trained on Charnley total hip replacements, the method is generic and so can be applied to radiographs of patients with any TJR. This paper shows that computer models can form the basis of a quick, automatic method of taking measurements from standard clinical radiographs.

Keyword(s)

Journal

Bibliographic metadata

Type of resource:
Content type:
Published date:
Volume:
211
Issue:
2
Start page:
145
End page:
154
Total:
10
Pagination:
145-154
Access state:
Active

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:115535
Created by:
Taylor, Christopher
Created:
30th January, 2011, 16:26:34
Last modified by:
Taylor, Christopher
Last modified:
13th August, 2012, 21:13:42

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.