In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Is the real-ear to coupler difference independent of the measurement earphone?

Munro, Kevin J; Salisbury, Vanessa A

International journal of audiology. 2002;41(7):408-13.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

Direct measurement of real-ear hearing aid performance can be obtained using a probe tube microphone system. Alternatively, it can be derived by adding the real-ear to coupler difference (RECD) to the electroacoustic performance of the hearing instrument measured in a 2-cc coupler. Inherent in this derivation is the assumption that the RECD measured with one transducer can be applied to a coupler measurement performed with a different transducer. For the RECD procedure to be valid, it should be independent of the measurement transducer. The Audioscan RM500 is an example of a commercially available real-ear measurement system that incorporates a clinical protocol for the measurement of the RECD. The RECD can be measured on the Audioscan RM500 using a standard EAR-Tone ER-3A insert earphone or the Audioscan's own RE770 insert earphone. The aim of this study was to compare the RECDs obtained with these two earphones. The Audioscan RM500 was used to measure the RECD from the right ears of 18 adult subjects ranging in age from 22 to 36 years (mean 25 years). Measurements were made with the EAR-Tone ER-3A and RE770 insert earphone and three earmould configurations: (1) the EARLINK foam ear-tip; (2) a hard acrylic shell earmould with the same length of acoustical tubing as the foam ear-tip (25 mm); and (3) the shell ear mould with the appropriate length of tubing for a behind-the-ear (BTE) hearing aid fitting (approximately 35-45 mm). The results show that the mean RECD was around 3 dB higher at 1.5 kHz with the foam ear-tip when measured with the RE770 earphone than when measured with the ER-3A earphone. The same magnitude of difference was obtained with the shell earmould and 25-mm tubing; however, this increased to 9 dB when the tubing was increased to around 40 mm for a BTE fitting. The difference in mean RECD with the two earphones was statistically significant on a repeated-measures ANOVA for every earmould configuration (p<0.001). The results of this study demonstrate that the RECD procedure that uses an HA2 coupler and earmould is not independent of the measurement earphone. This has important implications for clinical practice.

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Published date:
Abbreviated journal title:
ISSN:
Place of publication:
Canada
Volume:
41
Issue:
7
Pagination:
408-13
Digital Object Identifier:
10.3109/14992020209090418
Pubmed Identifier:
12403609
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:146779
Created by:
Munro, Kevin
Created:
10th January, 2012, 12:15:28
Last modified by:
Munro, Kevin
Last modified:
15th November, 2012, 01:07:40

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.