In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Comparison of bronchoprotective and bronchodilator effects of a single dose of formoterol delivered by hydrofluoroalkane and chlorofluorocarbon aerosols and dry powder in a double blind, placebo-controlled, crossover study.

Houghton C, Langley S, Singh SD, Holden J, Monici Preti A, Acerbi D, Poli G, Woodcock AA

Br J Clin Pharmacol. 2004;58( 4):359-66.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Use our list of Related resources to find this item elsewhere. Alternatively, request a copy from the Library's Document supply service.

Abstract

BACKGROUND: In response to the phasing out of chlorofluorocarbon (CFC) inhalers, a metered dose hydrofluoroalkane (HFA) formulation, Modulite (Chiesi Farmaceutici S.p.A, Parma, Italy), to be delivered with a pressurized metered dose inhaler (pMDI), has been developed. Modulite is a HFA formulation technology that has been designed to provide stable and uniform dose delivery of HFA-based formulations to enable an easy transition from CFC to HFA inhalers. OBJECTIVES: The aim of this study was to compare the bronchoprotective and bronchodilator effects of a single dose of 12 microg of formoterol from the HFA Modulite inhaler with the Foradil Aerolizer (dry powder inhaler, DPI) and the Foradil CFC inhalers (Novartis Health Consumer, Basel, Switzerland). METHODS: This was a double blind, double dummy, randomized, placebo-controlled, crossover study conducted in 38 subjects with mild to moderate asthma (mean forced expiratory volume in 1 s [FEV1] 87.5% predicted). The primary endpoint was methacholine challenge provocative dose required for 20% fall in the FEV1 (PD20) 90 min post dose. Bronchodilation was assessed with spirometry (FEV1, FVC, FEF25-75) and impulse oscillometry (resistance at 5 and 20 Hz, reactance at 5 Hz and resonant frequency) over the 90 min post dose. In a subset of 12 subjects formoterol plasma levels, serum potassium and glucose were determined up to 480 min post dose. RESULTS: The three formoterol formulations demonstrated significant (P < or = 0.05) improvements in bronchoprotection compared to placebo and non-inferiority of the HFA preparation compared to the CFC and DPI preparations was demonstrated. Geometric mean PD20 values were 0.51 mg with HFA, 0.62 mg with DPI, 0.62 mg with CFC and 0.2 mg with placebo. The log transformed mean differences in PD20 doubling dose between HFA and (a) DPI was -0.28 (95% CI -0.84-0.29, P = 0.57) (b) CFC was -0.28 (95% CI -0.84-0.28, P = 0.57) and (c) placebo was 1.38 (95% CI 0.82-1.94, P < 0.001). Serum potassium, glucose and formoterol plasma profiles were comparable for the CFC, HFA and DPI devices. CONCLUSION: Our findings of similar efficacy, pharmacokinetics and systemic effects of the HFA formoterol inhaler compared to the CFC and DPI preparations supports the potential use of this novel formulation in the treatment of asthma. Copyright 2004 Blackwell Publishing Ltd

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Published date:
Journal title:
ISSN:
Place of publication:
England
Volume:
58( 4)
Start page:
359
End page:
66
Pagination:
359-66
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:1d29137
Created:
2nd September, 2009, 11:45:41
Last modified:
7th July, 2014, 18:30:32

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.