In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Related resources

University researcher(s)

    Academic department(s)

    A Study to Develop a New Clinical Measure to Assess Visual Awareness in Tunnel Vision

    Al Shaghthrah, Ali

    [Thesis]. Manchester, UK: The University of Manchester; 2014.

    Access to files

    Abstract

    AbstractVisual conditions such as retinitis pigmentosa and Usher syndrome can gradually cause tunnel vision. Patients with these conditions usually face difficulties with navigation, avoiding obstacles, and performing visual search. Loss of mobility can affect patients' independence and quality of life. One of the rehabilitation strategies for patients with tunnel vision is the use of optical aids to enhance mobility performance. The main method used to evaluate the usefulness of optical aids is the patient’s subjective report after extended wear. In order to evaluate optical aid effectiveness in the clinic, a new test based on the visual search paradigm was designed to assess the patient's visual awareness. This was named the assessment of visual awareness (AVA) test. The main aim of this study was to develop the AVA test, establish its sensitivity, validity and repeatability, and then use it to investigate the efficacy of optical aids in this group of people.The AVA test consists of 32 peripheral targets presented at four different locations: 1st annulus (at 5° from the central fixation), 2nd annulus (10°), 3rd annulus (20°) and 4th annulus (30°)). In this study, the peripheral targets were presented singly against a spatial noise background in a presentation area of 81° H × 62° V. Participants were allowed to use head and eye movements and were asked to search for and locate each target. The detection time (DT) was recorded. A new, sensitive and easy to set up indoor mobility course was also designed and validated prior to its use in validating the AVA test.A total of 50 normally sighted participants with simulated tunnel vision (TV) (5° to 20°, in 5° steps) and 20 patients with TV (retained field 4° to 21°) were tested. The AVA test was found to be responsive to the change in field of view (FoV) and to the target locations in both groups of participants. In the simulated group, a significant relationship was found between FoV and DT at each annulus (r ranging from -0.55 to -0.77, p < 0.0001). A significant relationship was found between target location and DT within each FoV size (20°, 15°, 10° and 5°) (r ranging from 0.53 to 0.84, p < 0.0001). In the TV patients, a statistically significant relationship was found between FoV and DT at each annulus (r range from -0.40 to -0.60, p < 0.05). The target location was shown to have a significant relationship with the DT within each FoV size (r ranging from 0.50 to 0.60, p < 0.05). Finally, the AVA test was found to be significantly related to the simulated TV participants' performance on the indoor mobility course.The AVA test was used to assess the efficacy of three optical aids: the partial aperture prism (10 patients), the Tri-field prism (10 patients) and the reverse telescope (4 patients). The AVA test showed no significant improvement in DT with either of the prisms and the participants did not find these aids helpful. DT with the reverse telescope improved, but none of the participants were willing to use these on extended trial. The AVA test gave clear indications of the efficacy of each aid, a result which could affirm the importance of the AVA test. In conclusion, the AVA test was found to be sensitive, valid and repeatable. DT did not improve in either of the optical aids which were found to be unsuccessful, suggesting that the AVA could be a promising clinical test. However the aids which showed improved DT were not evaluated over the longer term, and therefore did not allow full evaluation of the AVA test.

    Bibliographic metadata

    Type of resource:
    Content type:
    Form of thesis:
    Type of submission:
    Degree programme:
    PhD Optometry
    Publication date:
    Location:
    Manchester, UK
    Total pages:
    396
    Abstract:
    AbstractVisual conditions such as retinitis pigmentosa and Usher syndrome can gradually cause tunnel vision. Patients with these conditions usually face difficulties with navigation, avoiding obstacles, and performing visual search. Loss of mobility can affect patients' independence and quality of life. One of the rehabilitation strategies for patients with tunnel vision is the use of optical aids to enhance mobility performance. The main method used to evaluate the usefulness of optical aids is the patient’s subjective report after extended wear. In order to evaluate optical aid effectiveness in the clinic, a new test based on the visual search paradigm was designed to assess the patient's visual awareness. This was named the assessment of visual awareness (AVA) test. The main aim of this study was to develop the AVA test, establish its sensitivity, validity and repeatability, and then use it to investigate the efficacy of optical aids in this group of people.The AVA test consists of 32 peripheral targets presented at four different locations: 1st annulus (at 5° from the central fixation), 2nd annulus (10°), 3rd annulus (20°) and 4th annulus (30°)). In this study, the peripheral targets were presented singly against a spatial noise background in a presentation area of 81° H × 62° V. Participants were allowed to use head and eye movements and were asked to search for and locate each target. The detection time (DT) was recorded. A new, sensitive and easy to set up indoor mobility course was also designed and validated prior to its use in validating the AVA test.A total of 50 normally sighted participants with simulated tunnel vision (TV) (5° to 20°, in 5° steps) and 20 patients with TV (retained field 4° to 21°) were tested. The AVA test was found to be responsive to the change in field of view (FoV) and to the target locations in both groups of participants. In the simulated group, a significant relationship was found between FoV and DT at each annulus (r ranging from -0.55 to -0.77, p < 0.0001). A significant relationship was found between target location and DT within each FoV size (20°, 15°, 10° and 5°) (r ranging from 0.53 to 0.84, p < 0.0001). In the TV patients, a statistically significant relationship was found between FoV and DT at each annulus (r range from -0.40 to -0.60, p < 0.05). The target location was shown to have a significant relationship with the DT within each FoV size (r ranging from 0.50 to 0.60, p < 0.05). Finally, the AVA test was found to be significantly related to the simulated TV participants' performance on the indoor mobility course.The AVA test was used to assess the efficacy of three optical aids: the partial aperture prism (10 patients), the Tri-field prism (10 patients) and the reverse telescope (4 patients). The AVA test showed no significant improvement in DT with either of the prisms and the participants did not find these aids helpful. DT with the reverse telescope improved, but none of the participants were willing to use these on extended trial. The AVA test gave clear indications of the efficacy of each aid, a result which could affirm the importance of the AVA test. In conclusion, the AVA test was found to be sensitive, valid and repeatable. DT did not improve in either of the optical aids which were found to be unsuccessful, suggesting that the AVA could be a promising clinical test. However the aids which showed improved DT were not evaluated over the longer term, and therefore did not allow full evaluation of the AVA test.
    Thesis main supervisor(s):
    Thesis co-supervisor(s):
    Thesis advisor(s):
    Language:
    en

    Institutional metadata

    University researcher(s):
    Academic department(s):

    Record metadata

    Manchester eScholar ID:
    uk-ac-man-scw:220523
    Created by:
    Al Shaghthrah, Ali
    Created:
    4th March, 2014, 12:19:37
    Last modified by:
    Al Shaghthrah, Ali
    Last modified:
    9th December, 2014, 10:30:00

    Can we help?

    The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.