In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

An Investigation Into Motion Correction Schemes For High Resolution 3D PET And PET/CT

Noonan, Philip John

[Thesis]. Manchester, UK: The University of Manchester; 2014.

Access to files

Abstract

Although motion correction in medical imaging is well established and has attracted much interest and research funding, a gap still exists in that there is a lack of reliable, low-cost hardware to enable such techniques to be widely adopted in healthcare. Motion correction of brain Positron Emission Tomography (PET) data for instance is an important step in realising the potential offered by modern high resolution PET scanners. Since it is not likely that subjects can remain stationary throughout the PET scan, which can last 60 minutes or more, accurate and reliable motion tracking is needed to correct the PET data for any observed motion. A commercially available marker based motion tracking system was evaluated and found to produce unreliable data. This was due to the possibility of the tracking tool slipping from the subject. This thesis describes the investigations into alternative and novel tracking techniques for use in PET. These included a markerless tracking system using the Microsoft Kinect (a low cost depth sensor) as well as a multiple target marker tracking system. The performance characteristics of both systems (low cost, high spatial and temporal accuracy, and real-time operation) were evaluated using phantom and clinical experiments. Investigations into using these two tracking techniques in whole body PET, specifically measuring the respiratory rate during lung imaging, were developed and compared against current commercially available solutions.

Layman's Abstract

Although motion correction in medical imaging is well established and has attracted much interest and research funding, a gap still exists in that there is a lack of reliable, low-cost hardware to enable such techniques to be widely adopted in healthcare. Motion correction of brain Positron Emission Tomography (PET) data for instance is an important step in realising the potential offered by modern high resolution PET scanners. Since it is not likely that subjects can remain stationary throughout the PET scan, which can last 60 minutes or more, accurate and reliable motion tracking is needed to correct the PET data for any observed motion. A commercially available marker based motion tracking system was evaluated and found to produce unreliable data. This was due to the possibility of the tracking tool slipping from the subject. This thesis describes the investigations into alternative and novel tracking techniques for use in PET. These included a markerless tracking system using the Microsoft Kinect (a low cost depth sensor) as well as a multiple target marker tracking system. The performance characteristics of both systems (low cost, high spatial and temporal accuracy, and real-time operation) were evaluated using phantom and clinical experiments. Investigations into using these two tracking techniques in whole body PET, specifically measuring the respiratory rate during lung imaging, were developed and compared against current commercially available solutions.

Bibliographic metadata

Type of resource:
Content type:
Form of thesis:
Type of submission:
Degree type:
Doctor of Philosophy
Degree programme:
PhD Medicine (Population Health) 4yr
Publication date:
Location:
Manchester, UK
Total pages:
188
Abstract:
Although motion correction in medical imaging is well established and has attracted much interest and research funding, a gap still exists in that there is a lack of reliable, low-cost hardware to enable such techniques to be widely adopted in healthcare. Motion correction of brain Positron Emission Tomography (PET) data for instance is an important step in realising the potential offered by modern high resolution PET scanners. Since it is not likely that subjects can remain stationary throughout the PET scan, which can last 60 minutes or more, accurate and reliable motion tracking is needed to correct the PET data for any observed motion. A commercially available marker based motion tracking system was evaluated and found to produce unreliable data. This was due to the possibility of the tracking tool slipping from the subject. This thesis describes the investigations into alternative and novel tracking techniques for use in PET. These included a markerless tracking system using the Microsoft Kinect (a low cost depth sensor) as well as a multiple target marker tracking system. The performance characteristics of both systems (low cost, high spatial and temporal accuracy, and real-time operation) were evaluated using phantom and clinical experiments. Investigations into using these two tracking techniques in whole body PET, specifically measuring the respiratory rate during lung imaging, were developed and compared against current commercially available solutions.
Layman's abstract:
Although motion correction in medical imaging is well established and has attracted much interest and research funding, a gap still exists in that there is a lack of reliable, low-cost hardware to enable such techniques to be widely adopted in healthcare. Motion correction of brain Positron Emission Tomography (PET) data for instance is an important step in realising the potential offered by modern high resolution PET scanners. Since it is not likely that subjects can remain stationary throughout the PET scan, which can last 60 minutes or more, accurate and reliable motion tracking is needed to correct the PET data for any observed motion. A commercially available marker based motion tracking system was evaluated and found to produce unreliable data. This was due to the possibility of the tracking tool slipping from the subject. This thesis describes the investigations into alternative and novel tracking techniques for use in PET. These included a markerless tracking system using the Microsoft Kinect (a low cost depth sensor) as well as a multiple target marker tracking system. The performance characteristics of both systems (low cost, high spatial and temporal accuracy, and real-time operation) were evaluated using phantom and clinical experiments. Investigations into using these two tracking techniques in whole body PET, specifically measuring the respiratory rate during lung imaging, were developed and compared against current commercially available solutions.
Thesis main supervisor(s):
Thesis co-supervisor(s):
Thesis advisor(s):
Funder(s):
Language:
en

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:224842
Created by:
Noonan, Philip
Created:
7th May, 2014, 11:43:36
Last modified by:
Noonan, Philip
Last modified:
1st August, 2014, 09:44:15

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.