In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Related resources

University researcher(s)

    Academic department(s)

      Automatic Artefact Removal and CO2 Prediction from the EEG Signals of Preterm Babies

      Buriro, Abdul Baseer

      [Thesis]. Manchester, UK: The University of Manchester; 2014.

      Access to files

      Abstract

      This dissertation describes research whose the purpose is to remove artefacts from the EEG signals of preterm neonates, thereby facilitating the prediction of carbon dioxide levels dissolved in the blood; this was achieved using key statistics obtained from the EEG. The EEG signals of neonates were recorded over a 24 – 36 hours period using LabVIEW (National Instruments) software and a XLTEK EMU40EX breakout head box with a 7- electrodes configuration. Raw EEG signals of neonates were processed using discrete wavelet transform multiresolution analysis to remove artefacts. A nonlinear energy operator was used to calculate the energy of the artefact-free neonate’s EEG signals. Threshold detection was used to find the bursts and the interburst intervals. Spectral power analysis was performed on every burst-interburst interval cycle to calculate the relative powers in the delta (0.5-3.5 Hz), theta (4.0-7.5 Hz), alpha (8-12.5 Hz), and beta (13-30 Hz) frequency bands in each burst-interburst interval cycle of the neonate’s EEG signals. A two minute arithmetic average of the interburst intervals, and the burst-interburst interval relative powers were used to develop a linear regression equation for the prediction of the carbon dioxide level. The EEG signals of different gestational age neonates were processed offline. Results were compared with the readings of ABL800 FLEX blood gas analyser (a blood gas machine) with a measuring range of 0.67 – 33.3 kilopascals. For the clean neonate’s EEG signals, the absolute prediction error lay between 0 – 1.0 kilopascals.

      Keyword(s)

      Artefact; CO2; Premature EEG

      Bibliographic metadata

      Type of resource:
      Content type:
      Form of thesis:
      Type of submission:
      Degree type:
      Master of Philosophy
      Degree programme:
      MPhil Electrical and Electronic Engineering
      Publication date:
      Location:
      Manchester, UK
      Total pages:
      69
      Abstract:
      This dissertation describes research whose the purpose is to remove artefacts from the EEG signals of preterm neonates, thereby facilitating the prediction of carbon dioxide levels dissolved in the blood; this was achieved using key statistics obtained from the EEG. The EEG signals of neonates were recorded over a 24 – 36 hours period using LabVIEW (National Instruments) software and a XLTEK EMU40EX breakout head box with a 7- electrodes configuration. Raw EEG signals of neonates were processed using discrete wavelet transform multiresolution analysis to remove artefacts. A nonlinear energy operator was used to calculate the energy of the artefact-free neonate’s EEG signals. Threshold detection was used to find the bursts and the interburst intervals. Spectral power analysis was performed on every burst-interburst interval cycle to calculate the relative powers in the delta (0.5-3.5 Hz), theta (4.0-7.5 Hz), alpha (8-12.5 Hz), and beta (13-30 Hz) frequency bands in each burst-interburst interval cycle of the neonate’s EEG signals. A two minute arithmetic average of the interburst intervals, and the burst-interburst interval relative powers were used to develop a linear regression equation for the prediction of the carbon dioxide level. The EEG signals of different gestational age neonates were processed offline. Results were compared with the readings of ABL800 FLEX blood gas analyser (a blood gas machine) with a measuring range of 0.67 – 33.3 kilopascals. For the clean neonate’s EEG signals, the absolute prediction error lay between 0 – 1.0 kilopascals.
      Keyword(s):
      Thesis main supervisor(s):
      Thesis co-supervisor(s):
      Thesis advisor(s):
      Language:
      en

      Institutional metadata

      University researcher(s):
      Academic department(s):

        Record metadata

        Manchester eScholar ID:
        uk-ac-man-scw:226361
        Created by:
        Buriro, Abdul Baseer
        Created:
        3rd June, 2014, 09:31:48
        Last modified by:
        Buriro, Abdul Baseer
        Last modified:
        9th March, 2016, 22:08:08