In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Related resources

Full-text held externally

University researcher(s)

Recommendations for the conduct of efficacy trials of treatment devices for osteoarthritis: a report from a working group of the Arthritis Research UK Osteoarthritis and Crystal Diseases Clinical Studies Group.

Felson, David T; Redmond, Anthony C; Conaghan, Philip G; Chapman, Graham J; Smith, Toby O; Hamilton, David F; Jones, Richard K; Holt, Cathy A; Callaghan, Michael J; Mason, Deborah J; Arthritis_Research_UK_Osteoarthritis_ and_Crystal_Diseases_Clinical_Studies_Group

Rheumatology (Oxford, England). 2016;55(2):320-326.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

OBJECTIVE: There are unique challenges to designing and carrying out high-quality trials testing therapeutic devices in OA and other rheumatic diseases. Such challenges include determining the mechanisms of action of the device and the appropriate sham. Design of device trials is more challenging than that of placebo-controlled drug trials. Our aim was to develop recommendations for designing device trials. METHODS: An Arthritis Research UK study group comprised of 30 rheumatologists, physiotherapists, podiatrists, engineers, orthopaedists, trialists and patients, including many who have carried out device trials, met and (using a Delphi-styled approach) came to consensus on recommendations for device trials. RESULTS: Challenges unique to device trials include defining the mechanism of action of the device and, therefore, the appropriate sham that provides a placebo effect without duplicating the action of the active device. Should there be no clear-cut mechanism of action, a three-arm trial including a no-treatment arm and one with presumed sham action was recommended. For individualized devices, generalizable indications and standardization of the devices are needed so that treatments can be generalized. CONCLUSION: A consensus set of recommendations for device trials was developed, providing a basis for improved trial design, and hopefully improvement in the number of effective therapeutic devices for rheumatic diseases.

Bibliographic metadata

Type of resource:
Content type:
Publication status:
Published
Publication type:
Publication form:
Published date:
Abbreviated journal title:
ISSN:
Volume:
55
Issue:
2
Start page:
320
End page:
326
Total:
6
Pagination:
320-326
Digital Object Identifier:
10.1093/rheumatology/kev328
Pubmed Identifier:
26361882
Pii Identifier:
kev328
Attached files embargo period:
Immediate release
Attached files release date:
25th January, 2016
Access state:
Active

Institutional metadata

University researcher(s):
Academic department(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:273159
Created by:
Ingram, Mary
Created:
18th September, 2015, 15:50:28
Last modified by:
Ingram, Mary
Last modified:
25th January, 2016, 13:41:46

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.