In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Polymer optical fibre sensor to monitor skin moisture

J. Vaughan, C. Woodyatt, P. J. Scully

In: Cutolo, Antonello; Culshaw, Brian ; Miguel Lpez-Higuera , Jose. Proc. SPIE, Vol. 6619, 66191T (2007); doi:10.1117/12.738650 : EWOFS-Third European Workshop on Optical Fibre Sensors; 07 Apr 2007-07 Jun 2007; Naples, Italy. SPIE; 2007.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Use our list of Related resources to find this item elsewhere. Alternatively, request a copy from the Library's Document supply service.

Abstract

We present a polymer optical fibre sensor to sense skin moisture and droplet formation when sweating occurs. Thesensor used evanescent field attenuation, by exploiting a moisture sensitive cladding with moisture indicator(fluorescein) contained within a porous cladding (HEMA). The sensor was designed to be comfortable to wear andunobtrusive, hygienic, with sterilised interchangeable sensing elements. It had maximum sensitivity between 98% and100% humidity, and response time of 24 seconds.

Bibliographic metadata

Type of resource:
Content type:
Type of conference contribution:
Publication date:
Conference title:
EWOFS-Third European Workshop on Optical Fibre Sensors
Conference venue:
Naples, Italy
Conference start date:
2007-04-07
Conference end date:
2007-06-07
Publisher:
Abstract:
We present a polymer optical fibre sensor to sense skin moisture and droplet formation when sweating occurs. Thesensor used evanescent field attenuation, by exploiting a moisture sensitive cladding with moisture indicator(fluorescein) contained within a porous cladding (HEMA). The sensor was designed to be comfortable to wear andunobtrusive, hygienic, with sterilised interchangeable sensing elements. It had maximum sensitivity between 98% and100% humidity, and response time of 24 seconds.

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:69236
Created by:
Scully, Patricia
Created:
24th October, 2009, 00:20:19
Last modified by:
Scully, Patricia
Last modified:
7th August, 2013, 18:53:28

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.