In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

EFFECT OF FLOW ON ELECTROCHEMICAL NOISE GENERATION

Shaglouf, Mukhtar Mohamed A

[Thesis]. Manchester, UK: The University of Manchester; 2010.

Access to files

Abstract

It is known that, in addition to corrosion processes, the electrochemical noise (EN) can be generated by some other disturbances such as mass transfer and flow turbulence. In this study the influence of both laminar and turbulent flow on the characteristics of electrochemical noise (EN) has been studied using a carbon steel rotating cylinder electrode (RCE) in aerated neutral (pH=7) 0.1 M NaCl and 0.1 M NaCl+0.1 M NaNO2 solutions. The RCE has a set of four graphite brushes for electrical connection. The supplied cathodic current was applied through the top two graphite brushes and measured the specimen potential through the bottom two to eliminate any expected cyclic variations in the measured potential.Prior to the measurement of EN, calibration of the mass transport properties of the electrode was performed by measuring the limiting current density for oxygen reduction as a function of rotation speed in order to estimate the transition from laminar to turbulent flow regime. EN experiments have been performed in free corrosion conditions (uninhibited and inhibited solutions), and with applied cathodic polarisation in the regions of hydrogen evolution and oxygen reduction processes. In the case of oxygen reduction and hydrogen evolution cathodic reactions it has been found that laminar flow had a negligible effect on the noise produced but a significant increase in the amplitude of the noise was observed in turbulent flow. On the other hand in free corrosion conditions in uninhibited solution the influence of flow was relatively insignificant and that was attributed to the low impedance of the corroding electrode. It is claimed that flow has a negligible effect in inhibited solutions due to the passivity of the system, which is responsible for the low rate of both anodic and cathodic reactions. Finally spectral analysis showed that the noise produced by turbulent flow had power at significantly higher frequencies than is normal for corrosion-related noise

Additional content not available electronically

CD contains ENM data

Bibliographic metadata

Type of resource:
Content type:
Form of thesis:
Type of submission:
Degree type:
Doctor of Philosophy
Degree programme:
PhD Materials
Publication date:
Location:
Manchester, UK
Total pages:
171
Abstract:
It is known that, in addition to corrosion processes, the electrochemical noise (EN) can be generated by some other disturbances such as mass transfer and flow turbulence. In this study the influence of both laminar and turbulent flow on the characteristics of electrochemical noise (EN) has been studied using a carbon steel rotating cylinder electrode (RCE) in aerated neutral (pH=7) 0.1 M NaCl and 0.1 M NaCl+0.1 M NaNO2 solutions. The RCE has a set of four graphite brushes for electrical connection. The supplied cathodic current was applied through the top two graphite brushes and measured the specimen potential through the bottom two to eliminate any expected cyclic variations in the measured potential.Prior to the measurement of EN, calibration of the mass transport properties of the electrode was performed by measuring the limiting current density for oxygen reduction as a function of rotation speed in order to estimate the transition from laminar to turbulent flow regime. EN experiments have been performed in free corrosion conditions (uninhibited and inhibited solutions), and with applied cathodic polarisation in the regions of hydrogen evolution and oxygen reduction processes. In the case of oxygen reduction and hydrogen evolution cathodic reactions it has been found that laminar flow had a negligible effect on the noise produced but a significant increase in the amplitude of the noise was observed in turbulent flow. On the other hand in free corrosion conditions in uninhibited solution the influence of flow was relatively insignificant and that was attributed to the low impedance of the corroding electrode. It is claimed that flow has a negligible effect in inhibited solutions due to the passivity of the system, which is responsible for the low rate of both anodic and cathodic reactions. Finally spectral analysis showed that the noise produced by turbulent flow had power at significantly higher frequencies than is normal for corrosion-related noise
Additional digital content not deposited electronically:
CD contains ENM data
Thesis main supervisor(s):
Language:
en

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:86380
Created by:
Shaglouf, Mukhtar
Created:
13th July, 2010, 14:02:42
Last modified by:
Shaglouf, Mukhtar
Last modified:
7th April, 2011, 10:19:16