In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

The effect of blood inflow and B1-field inhomogeneity on measurement of the arterial input function in axial 3D spoiled gradient echo dynamic contrast-enhanced MRI

C. Roberts, R. Little, Y. Watson, S. Zhao, D.L. Buckley, G.J.M. Parker

Magnetic Resonance in Medicine. 2011;65(1):108-119.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

A major potential confound in axial 3D dynamic contrast-enhanced magnetic resonance imaging studies is the blood inflow effect; therefore, the choice of slice location for arterial input function measurement within the imaging volume must be considered carefully. The objective of this study was to use computer simulations, flow phantom, and in vivo studies to describe and understand the effect of blood inflow on the measurement of the arterial input function. All experiments were done at 1.5 T using a typical 3D dynamic contrast-enhanced magnetic resonance imaging sequence, and arterial input functions were extracted for each slice in the imaging volume. We simulated a set of arterial input functions based on the same imaging parameters and accounted for blood inflow and radiofrequency field inhomogeneities. Measured arterial input functions along the vessel length from both in vivo and the flow phantom agreed with simulated arterial input functions and show large overestimations in the arterial input function in the first 30 mm of the vessel, whereas arterial input functions measured more centrally achieve accurate contrast agent concentrations. Use of inflow-affected arterial input functions in tracer kinetic modeling shows potential errors of up to 80% in tissue microvascular parameters. These errors emphasize the importance of careful placement of the arterial input function definition location to avoid the effects of blood inflow.

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Publication form:
Published date:
Volume:
65
Issue:
1
Start page:
108
End page:
119
Digital Object Identifier:
10.1002/mrm.22593
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:95939
Created by:
Parker, Geoffrey
Created:
23rd November, 2010, 19:57:43
Last modified by:
Parker, Geoffrey
Last modified:
25th December, 2014, 20:58:15

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.