In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Real-ear to coupler differences in children with grommets.

Martin, H C; Munro, K J; Langer, D H

British journal of audiology. 1997;31(1):63-9.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

Real-ear to coupler differences (RECDs) are important for the selection of appropriate amplification characteristics for hearing impaired children. The aim of this study was to investigate the effects of patent grommets on RECDs in children. Subjects were 32 children aged between 4 and 7 years, 16 had a patent grommet in one or both ears as confirmed by otoscopy and large equivalent ear canal volumes on tympanometry. There was no evidence of middle ear pathology in the remaining 16 who comprised the control group. All real-ear and coupler measures showed good test-retest repeatability across the whole frequency range. The mean difference in RECDs between the two groups in the frequency range 0.125-0.75 kHz was 15 dB. The differences in RECDs were statistically significant (P < 0.01) for all frequencies below 0.75 kHz. There was a strong correlation between the mean RECD and equivalent ear canal volume at all frequencies between 0.125 and 0.5 kHz, and a moderate correlation at 0.75 kHz. Large inter-subject variability was found, with a maximum standard deviation of 6.6 dB at 4.0 kHz. Therefore, this study supports the need for individual RECD measures to be made, particularly for subjects with grommets, rather than using averaged transformation figures. It suggests that more low frequency gain should be given to hearing aid users with patent grommets to overcome the reduced SPL in the ear canal, due to leakage through the vented tympanic membrane.

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Published date:
Abbreviated journal title:
ISSN:
Place of publication:
ENGLAND
Volume:
31
Issue:
1
Pagination:
63-9
Pubmed Identifier:
9056044
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:146787
Created by:
Munro, Kevin
Created:
10th January, 2012, 12:15:46
Last modified by:
Munro, Kevin
Last modified:
10th January, 2012, 12:15:46

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.