In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Measurement of macular pigment optical density and distribution using the steady-state visual evoked potential

Robson, Anthony G; Parry, Neil R A

Visual Neuroscience. 2008;25(4):575-583.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

The purpose of this study was to specify isoluminance at different retinal eccentricities and to characterize macular pigment optical density (MPOD) and distribution using the steady-state visual evoked potential (VEP). Red-green (R/G) and blue-green (B/G) gratings were generated within two circular stimulus fields (radius = 0.55 or 1.1 deg) and within four annular fields (maximum mean radius = 6.0 deg) on a color monitor. Temporal frequency was 15 Hz. Isoluminance was determined for each stimulus using minimum flicker photometry. Steady-state onset-offset VEPs were recorded to the same annular stimuli as the luminance ratio between adjacent chromatic components was changed from 0.25 to 0.85 in 11 automated steps (0.5 representing photometric isoluminance). Fourier analysis showed that the power of the first harmonic was minimized at the isoluminant ratio specific to each subject. Relative OD was computed by comparing the isoluminant ratio at any location with that for the most eccentric annulus. To compensate for the broadband characteristics of the monitor, OD values were corrected according to minimum flicker measurements made through known concentrations of carotenoid solution. MPOD was additionally measured using minimum motion photometry. There was high correlation between the isoluminant ratios determined by minimum flicker and VEPs for both R/G and B/G stimulation (r = 0.91, P < 0.005, slope = 1). Calibrated OD values computed from VEP estimates of B/G isoluminance correlated with those derived from minimum flicker (r = 0.96, P < 0.0005, slope = 0.85) and motion photometry (r = 0.94, P < 0.0005, slope = 0.88). OD values derived from B/G VEPs increased toward the fovea and corresponded closely with minimum flicker and minimum motion assessment of MP distribution profiles. The steady-state VEP can be used to determine isoluminance at different retinal eccentricities. MPOD and distribution can be measured by steady-state VEPs to B/G stimuli.

Bibliographic metadata

Type of resource:
Content type:
Published date:
Journal title:
ISSN:
Volume:
25
Issue:
4
Start page:
575
End page:
583
Total:
9
Pagination:
575-583
Digital Object Identifier:
10.1017/s0952523808080681
ISI Accession Number:
WOS:000259176500005
Related website(s):
  • Related website <Go to ISI>://WOS:000259176500005
General notes:
  • Times Cited: 3
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:158322
Created by:
Parry, Neil
Created:
30th March, 2012, 12:10:44
Last modified by:
Parry, Neil
Last modified:
13th August, 2012, 19:00:41

Can we help?