In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Monitoring blood loss with near infrared spectroscopy.

Torella F, Cowley R, Thorniley MMS, McCollum C

Brit Journal of Surgery. 2002;88(5):753-753.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Use our list of Related resources to find this item elsewhere. Alternatively, request a copy from the Library's Document supply service.

Abstract

Experimental research has shown correlation between near infrared spectroscopy (NIRS) and blood loss, but these findings have not been validated in man. Ten blood donors were monitored before, during and for 10 min after blood collection (470 ml) with NIRS. A Somanetics INVOS 4100 oximeter monitored regional haemoglobin saturation in the cerebral cortex (cSO(2)-left frontal area) and from the left calf (pSO(2)). A Critikon 2001 Cerebral Redox Model monitored total (tHb), oxygenated (O(2)Hb) and deoxygenated (HHb) haemoglobin from the right calf. The oxygenation index [HbD]=[O(2)Hb]-[HHb] was derived from the data. cSO(2) (P<0.001), pSO(2) (P<0.001) and HbD (P=0.001) decreased during blood collection. Maximum changes occurred 10 minutes after collection for cSO(2), with a mean fall (95% C.I.) of 2.5 (-0.06-4.86)%, at the end of blood collection for pSO(2), with a mean fall (95% C.I.) of 3 (0.74-5.26)% and after 8% of blood volume loss for HbD, with a mean fall (95% C.I.) of 7.2 (2.25-12.16). Cerebral and peripheral oxygenation did not recover after blood collection. There was good correlation between NIRS parameters and blood loss. NIRS is a potentially useful technique for monitoring blood loss in humans. Further research is needed to define its role in clinical practice.

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Publication form:
Published date:
Journal title:
ISSN:
Place of publication:
United States
Volume:
88
Issue:
5
Start page:
753
End page:
753
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:1d20907
Created:
30th August, 2009, 15:53:57
Last modified by:
Thorniley, Maureen
Last modified:
4th January, 2011, 19:34:18

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.