In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Related resources

University researcher(s)

    Breath Analysis for Diagnosis of Ventilator-Associated Pneumonia

    Van Oort, Pouline Maria Petra

    [Thesis]. Manchester, UK: The University of Manchester; 2016.

    Access to files

    Abstract

    Introduction: Mechanical ventilation on the Intensive Care Unit (ICU) is a life-saving intervention but can be associated with the development of ventilator-associated pneumonia (VAP). Diagnosing VAP remains challenging and many patients receive antimicrobial treatment unnecessarily, contributing to the well-known global problem of antimicrobial resistance. Breath analysis offers a novel diagnostic perspective in critically ill mechanically ventilated patients. Two breath sampling methods have already been developed and shall be investigated in patients suspected of VAP on ICU. Thus proof will be sought that these volatile compounds can distinguish between the presence and absence of VAP.Methods: A ventilator circuit was constructed to model the patient setting on ICU. Two methods of breath sampling were investigated: 1) a semi-invasive method using a suction catheter inserted via the endotracheal tube; and 2) a non-invasive method that sampled in the external ventilator connection circuit. A quality control (QC) mix was inserted in the ventilator circuit. Samples were collected on steel adsorbent tubes, which were analysed using Thermal Desorption – Gas Chromatography – Mass Spectrometry (TD – GC – MS). On three ICUs in Greater Manchester a proof-of-concept study was set up to test both breath sampling techniques in critically ill patients suspected of VAP.Results: Both breath sampling methods resulted in good chromatograms reflecting signals deriving from the compounds of the QC mix. The compounds with relatively large molecular weight were not sampled as well using the non-invasive compared to the semi-invasive method. The semi-invasive method resulted in contaminating signals on the chromatograms. The clinical study suffers from a low recruitment rate, which appears to be due to a reduction in the prevalence of VAP on the participating ICUs. Discussion: A realistic model of human mechanical ventilation was established. A QC mix mimicking compounds present in exhaled breath was successfully inserted in the system and sampled using non-invasive and semi-invasive breath sampling methods. Standard curve linearity and detection limits of the system were determined. The clinical study is currently recruiting and data is being collected.

    Bibliographic metadata

    Type of resource:
    Content type:
    Form of thesis:
    Type of submission:
    Degree type:
    Master of Philosophy
    Degree programme:
    MPhil Medicine FT (IIRM)
    Publication date:
    Location:
    Manchester, UK
    Total pages:
    196
    Abstract:
    Introduction: Mechanical ventilation on the Intensive Care Unit (ICU) is a life-saving intervention but can be associated with the development of ventilator-associated pneumonia (VAP). Diagnosing VAP remains challenging and many patients receive antimicrobial treatment unnecessarily, contributing to the well-known global problem of antimicrobial resistance. Breath analysis offers a novel diagnostic perspective in critically ill mechanically ventilated patients. Two breath sampling methods have already been developed and shall be investigated in patients suspected of VAP on ICU. Thus proof will be sought that these volatile compounds can distinguish between the presence and absence of VAP.Methods: A ventilator circuit was constructed to model the patient setting on ICU. Two methods of breath sampling were investigated: 1) a semi-invasive method using a suction catheter inserted via the endotracheal tube; and 2) a non-invasive method that sampled in the external ventilator connection circuit. A quality control (QC) mix was inserted in the ventilator circuit. Samples were collected on steel adsorbent tubes, which were analysed using Thermal Desorption – Gas Chromatography – Mass Spectrometry (TD – GC – MS). On three ICUs in Greater Manchester a proof-of-concept study was set up to test both breath sampling techniques in critically ill patients suspected of VAP.Results: Both breath sampling methods resulted in good chromatograms reflecting signals deriving from the compounds of the QC mix. The compounds with relatively large molecular weight were not sampled as well using the non-invasive compared to the semi-invasive method. The semi-invasive method resulted in contaminating signals on the chromatograms. The clinical study suffers from a low recruitment rate, which appears to be due to a reduction in the prevalence of VAP on the participating ICUs. Discussion: A realistic model of human mechanical ventilation was established. A QC mix mimicking compounds present in exhaled breath was successfully inserted in the system and sampled using non-invasive and semi-invasive breath sampling methods. Standard curve linearity and detection limits of the system were determined. The clinical study is currently recruiting and data is being collected.
    Thesis main supervisor(s):
    Thesis co-supervisor(s):
    Language:
    en

    Institutional metadata

    University researcher(s):
    Academic department(s):

    Record metadata

    Manchester eScholar ID:
    uk-ac-man-scw:305316
    Created by:
    Van Oort, Pouline
    Created:
    28th October, 2016, 13:16:08
    Last modified by:
    Van Oort, Pouline
    Last modified:
    3rd March, 2017, 10:20:58

    Can we help?

    The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.