In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Development of a novel Colour X-ray Coherent Scatter Imaging system

Hansson, Conny

[Thesis]. Manchester, UK: The University of Manchester; 2010.

Access to files

Abstract

The field of X-ray imaging and X-ray diffraction have been combined in a new techniquecalled Tomographic Energy Dispersive Diffraction Imaging (TEDDI). This diffraction imaging technique allows 3D sample images to be obtained, non-destructively, where each imaged point contains the atomic structural information associated with its diffraction pattern. The main drawback of the TEDDI technique is the long collection times needed to produce the images. In order to overcome this obstacle the rapid TEDDI (rTEDDI) system has been developed at the University of Manchesters Material Science Centre. The research and development of rTEDDI has been the focus of this PhD thesis.A proof of concept for the rTEDDI imaging technique was obtained using thin samples on station 7.6 SRS Daresbury. In this case a first generation array collimator was used in conjunction with an energy resolving Si pixelated detector. Structural information such as lattice parameters, crystal system and phase identiffcation were obtained for metal, polymer and deer antler bone samples. The use of high Z semiconductor detector material was investigated in order to increase the potential of TEDDI for larger and more dense samples. To enable penetration of larger samples high energy X-rays needed to be utilized. In order to detect these higher energies with a good efficiency the detector media was changed from Si to CdZnTe (CZT).The second generation rTEDDI, using CZT as the detection media, was intended to be used under high flux/high energy synchrotron radiation conditions. Testing of the system under these conditions on station 16.3 SRS Daresbury showed an inability to produce diffraction imaging. An in depth investigation into detector and collimator array performance showed a two fold cause. The ERD2004 detector was unable to handle the high countrates experienced during high flux/high energy synchrotron radiation conditions. The MK1.2 collimator array was found to become partially transparent to X-ray energies around the absorption edge of W resulting in the swamping of the diffraction signal under high flux/high energy synchrotron radiation conditions. A new detector Application Specific Integrated Circuit (ASIC) design, developed by the detector division and the Rutherford Appleton Laboratory, and Data Aquisition (DAQ) system, developed by Aspect Systems, as well as a number of new collimator array designs were developed and tested. Testing of the new collimator array structures have shown positive results and the new HEXITECdetector which was designed to be able to handle high countrates, have shown an unprecedented inter pixel uniformity and energy resolution which have been attributed to the ASIC performance and the use of better quality CZT material.

Bibliographic metadata

Type of resource:
Content type:
Form of thesis:
Type of submission:
Degree type:
PhD
Degree programme:
PhD Materials Science
Publication date:
Location:
Manchester, UK
Total pages:
225
Abstract:
The field of X-ray imaging and X-ray diffraction have been combined in a new techniquecalled Tomographic Energy Dispersive Diffraction Imaging (TEDDI). This diffraction imaging technique allows 3D sample images to be obtained, non-destructively, where each imaged point contains the atomic structural information associated with its diffraction pattern. The main drawback of the TEDDI technique is the long collection times needed to produce the images. In order to overcome this obstacle the rapid TEDDI (rTEDDI) system has been developed at the University of Manchesters Material Science Centre. The research and development of rTEDDI has been the focus of this PhD thesis.A proof of concept for the rTEDDI imaging technique was obtained using thin samples on station 7.6 SRS Daresbury. In this case a first generation array collimator was used in conjunction with an energy resolving Si pixelated detector. Structural information such as lattice parameters, crystal system and phase identiffcation were obtained for metal, polymer and deer antler bone samples. The use of high Z semiconductor detector material was investigated in order to increase the potential of TEDDI for larger and more dense samples. To enable penetration of larger samples high energy X-rays needed to be utilized. In order to detect these higher energies with a good efficiency the detector media was changed from Si to CdZnTe (CZT).The second generation rTEDDI, using CZT as the detection media, was intended to be used under high flux/high energy synchrotron radiation conditions. Testing of the system under these conditions on station 16.3 SRS Daresbury showed an inability to produce diffraction imaging. An in depth investigation into detector and collimator array performance showed a two fold cause. The ERD2004 detector was unable to handle the high countrates experienced during high flux/high energy synchrotron radiation conditions. The MK1.2 collimator array was found to become partially transparent to X-ray energies around the absorption edge of W resulting in the swamping of the diffraction signal under high flux/high energy synchrotron radiation conditions. A new detector Application Specific Integrated Circuit (ASIC) design, developed by the detector division and the Rutherford Appleton Laboratory, and Data Aquisition (DAQ) system, developed by Aspect Systems, as well as a number of new collimator array designs were developed and tested. Testing of the new collimator array structures have shown positive results and the new HEXITECdetector which was designed to be able to handle high countrates, have shown an unprecedented inter pixel uniformity and energy resolution which have been attributed to the ASIC performance and the use of better quality CZT material.
Thesis main supervisor(s):
Funder(s):
Language:
en

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:80396
Created by:
Hansson, Conny
Created:
7th May, 2010, 17:05:46
Last modified by:
Hansson, Conny
Last modified:
17th June, 2011, 20:54:06

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.