In April 2016 Manchester eScholar was replaced by the University of Manchester’s new Research Information Management System, Pure. In the autumn the University’s research outputs will be available to search and browse via a new Research Portal. Until then the University’s full publication record can be accessed via a temporary portal and the old eScholar content is available to search and browse via this archive.

Orientationally invariant indices of axon diameter and density from diffusion MRI

D.C. Alexander, P.L. Hubbard, M.G. Hall, E.A. Moore, M. Ptito, G.J.M. Parker, T.B. Dyrby

Neuroimage. 2010;52(4):1374-1389.

Access to files

Full-text and supplementary files are not available from Manchester eScholar. Full-text is available externally using the following links:

Full-text held externally

Abstract

This paper proposes and tests a technique for imaging orientationally invariant indices of axon diameter and density in white matter using diffusion magnetic resonance imaging. Such indices potentially provide more specific markers of white matter microstructure than standard indices from diffusion tensor imaging. Orientational invariance allows for combination with tractography and presents new opportunities for mapping brain connectivity and quantifying disease processes. The technique uses a four-compartment tissue model combined with an optimized multishell high-angular-resolution pulsed-gradient-spin-echo acquisition. We test the method in simulation, on fixed monkey brains using a preclinical scanner and on live human brains using a clinical 3 T scanner. The human data take about one hour to acquire. The simulation experiments show that both monkey and human protocols distinguish distributions of axon diameters that occur naturally in white matter. We compare the axon diameter index with the mean axon diameter weighted by axon volume. The index differs from this mean and is protocol dependent, but correlation is good for the monkey protocol and weaker, but discernible, for the human protocol where greater diffusivity and lower gradient strength limit sensitivity to only the largest axons. Maps of axon diameter and density indices from the monkey and human data in the corpus callosum and corticospinal tract reflect known trends from histology. The results show orientationally invariant sensitivity to natural axon diameter distributions for the first time with both specialist and clinical hardware. This demonstration motivates further refinement, validation, and evaluation of the precise nature of the indices and the influence of potential confounds

Bibliographic metadata

Type of resource:
Content type:
Publication type:
Publication form:
Published date:
Journal title:
ISSN:
Publisher:
Volume:
52
Issue:
4
Start page:
1374
End page:
1389
Total:
16
Pagination:
1374-1389
Digital Object Identifier:
10.1016/j.neuroimage.2010.05.043
Access state:
Active

Institutional metadata

University researcher(s):

Record metadata

Manchester eScholar ID:
uk-ac-man-scw:95685
Created by:
Parker, Geoffrey
Created:
21st November, 2010, 12:25:36
Last modified by:
Parker, Geoffrey
Last modified:
27th October, 2015, 10:46:29

Can we help?

The library chat service will be available from 11am-3pm Monday to Friday (excluding Bank Holidays). You can also email your enquiry to us.